In 1979, Unit 1 was constructed with a dual-alkali scrubber to help reduce sulphur dioxide (SO2) emissions. In 1986, Unit 2 was completed and also uses a dual-alkali scrubber. From 2001 to 2005, Vectren installed four selective catalytic reduction (SCR) devices on all of the coal-fired units, which successfully cut nitrogen oxide (NOx) emissions by 80 percent. In 2004, Vectren replaced an existing electrostatic precipitator at Unit 1 with a fabric filter. The investment increased the particulate matter removal efficiency to 99 percent at that unit.
Ash ponds
The A. B. Brown Station ash management impoundment was formed by building a dam to block off the outlet of a natural ravine about 0.5 miles (0.8 km) from the Ohio river. The ash pond consists of two dams. The Lower dam (built in 1978) has been classified by the Indiana DNR as a Significant Hazard (State ID#65-7, permit #D-4405, rev 1). The Upper dam (constructed in two phases in 2002 and 2007) was not classified, but has a permit #FW-21909. Liquid wastes being sluiced into the pond include fly ash, bottom ash, boiler slag, FGD belt filter wash down and water sump wastes, pyrites, material removed from the coal pile run-off pond, plant floor drain wash downs, boiler chemical leaning wastes, reverse osmosis system rejects, and rainfall/runoff from the surrounding area. According to Vectren, no discernible amount of material has been removed from the pond since it first began operation in 1978.